The operator is be ckeched at least twice a year, including its rail and roller clearing.
Door Direction: since you have bought a bi-parting door, you may turn the switch for the so-called "Opening Direction" to the right hand side, then press TEST in order to see if it functions properly.
1.The power of the access control (the control unit that is to be installed) must be at AC 24V or DC24-36V.
2.The detector of your access control must be switched to "Normally Open Detector without Voltage".
3.Connect the first two wires on the access control to the AC24V or DC24-36V power bushing (GRIZZLY terminal unit), and the other two wires should be connected with the bushings for "Normally Open Detector" on the access control.
Its life cylce is at least at 2 million door movements -equivalent to more or less 7 years.
You must first remove all the sensor wires from the controller and press TEST to see whether the controller functions well without a sensor attached. If that is the case, it means that the sensor is improperly installed and you might have to reinstall it using the Installation Manual.